香港黄大仙码报要钱料
PerkinElmer

气相色谱质谱(GC / MS)

OF

当今的实验室需要并希望通过色谱实现更多的分析应用,因此许多人已经转向使用质谱来获取更精确的数据。我们成熟质谱解决方案可以满足您日益增长的分析实验室要求。我们的GC/MS系统适用于大多数应用,如食品、环境、工业和法医分析等领域。

为了识别和定量挥发性和半挥发性化合物,无缝集成的Clarus?SQ 8 GC/MS可实现高通量?#26696;?#28789;敏度,可满足最严格的环境要求。食品供应商有能力应对质量和安全挑战。工业公司可以改善其产品的质量和安全性。取证实验室可以更快地获得实验结果,以应对紧急的事件。

如果您不了解样品中的成分,我们的AxION? iQT? GC/MS/MS给为您提供答案。专为目标和非目标成分分析而设计,可为样品提供卓越的表征,是化学化工、石油、食品和个人护理产品应用的理想选择。

通过我们易于操作(和携带)Torion? T-9便携式GC/MS,您可以将实验室带到样品现场。Torion专为现场检测而设计,采用LTM(低热质)毛细管色谱柱的气相色谱可以提供足以与实验室色谱仪器相媲美的色谱分离效果及表现。从运行复杂分析的高性能台式系统到应对最?#37327;?#30340;现场应用,我们拥有合适的GC/MS解决方案来满足您的需求,帮您实现更快,更好和更自信的决策。

Business Insights (9)
Filters:

1-9 的 9 Business Insights

  • 产品?#24471;?/span>

    Torion T-9 GC MS

    Although it was built for portability and speed, the low thermal mass (LTM) capillary GC provides equivalent chromatographic resolution and performance to a benchtop system. The miniature size is achieved by replacing a conventional convectively-heated column oven with a low thermal mass (LTM) column bundle with direct-contact electrical resistive heating. LTM GC uses a small diameter, metal capillary GC column, which is bundled with resistive heating and temperature-sensing wires that are braided Superior technology ? Small diameter LTM capillary GC for high speed, high resolution separation of chemical analytes ? Rapid temperature programming delivers analysis times of under three min. ? Sensitive and selective mass-based detection of a wide range of chemicals ? Easy to operate with a color touch-screen display and simple navigation buttons Figure 1. The Torion T-9 Low Thermal Mass Capillary GC is fast and operates reliably. Injection Port with Removable Liner LTM Capillary Column Bundle Cooling Fan Electronic Pressure Control GC Electronic Board together with insulator strands. This design provides for greater heating and cooling speeds and very low power consumption

  • 应用文献

    Identification of VOCs in In-Vehicle Interior

    Customer complaints of odors within a new car are rising with the increasing number of new car buyers. Although odors can be subjective, it is now well known that the new car smell is the result of chemicals emitted from the in-vehicle interior components such as the dashboard, interior panels, seat coverings, flooring materials, and so on. This application note describes a method for the automotive industry that provides a qualitative analysis and the olfactory character of each component using the TD-GC/MS-Olfactory Port.

  • 应用文献

    Rapid Identification of Illicit Drug Substances

    This study describes the injection, separation, and identification of 16 drugs compunds in less than 10 minutes using portable gas chromatograph-toroidal ion trap mass spectrometry (PerkinElmer, Torion T-9 Portable GC/MS) combined with a coiled-wire-filament (CWF) sampling injector to provide an effective tool for onsite analysis of illicit drugs substances.

  • 应用文献

    Method 8260C by Purge and Trap Gas Chromatography Mass Spectrometry using the Clarus SQ 8

    This method outlines the analysis of volatile organic compounds in a variety of solid waste matrices including various air sampling trapping media, ground and surface water, soils, and sediments among others. The method requires not only demonstration of laboratory sample preparation and handling competence but instrument performance as well. The study presented here demonstrates the PerkinElmer? Clarus? SQ 8 GC/MS with purge and trap sample introduction both meets and exceeds the performance criteria set out in method 8260C and describes the analytical results and instrumental methodology.

  • 应用文献

    Rapid In-Field Screening for Fentanyl Analogs

    In recent years there has been an increase in fatalities related to the use and consumption of opioids, a class of synthetically manufactured pain-relieving drugs similar to naturally derived opiates like morphine, opium, codeine, and heroin. This application demonstrates the use of the novel Custodion? Coiled Microextraction (CME) syringes and the Torion T-9 Portable GC/MS as a fast and easy to use screening tool for drugs of abuse and new psychoactive substances (NPS) in the field.

  • 应用文献

    Determination of 2,4,6-Trichlorophenol in water by Derivatization in headspace and GC/MS

    Chlorophenols are by-products of the drinking water purification process and are also widely used as wood preservatives, herbicides and pesticides. In this study, the derivatization and extraction happened in the headspace vials during the vial thermostatting step. The derivatization reaction is affected by temperature and time, therefore the thermostat time and oven temperature of the headspace sampler were investigated for optimum derivitization/extraction conditions.

  • 应用文献

    Determination of Volatile Organic Compounds in Soils

    Volatile organic compounds (VOCs) are a series of compounds with boiling points from 50 to 250 degrees centigrade and are widely used as industrial chemicals/ solvents. Low concentrations of VOCs can have a significant impact on human health, as many are regarded as highly toxic, refractory and carcinogenic. The detection and determination of VOCs in the environment is of the upmost importance for both human and environmental health.

  • 文章

    Optimization of Method EPA 325 for Monitoring of VOCs Around Oil Refinery Fencelines

    This study will demonstrate how the GC instrumental parameters are optimized so that VOCs, in addition to semi-volatile organic compounds (SVOCs), can be analyzed on the same instrumentation enabling enhanced throughput and laboratory efficiency. It will also discuss the number of samples required by each refinery depending on its size, in addition to the distribution of sampling sites around the refinery.

  • 文章

    Extending the Hydrocarbon Range for the Analysis of Soil Gas Samples Using ATD with GC/MS

    This study describes the recovery of compounds above the boiling point of naphthalene achieved by optimizing the thermal desorption chemistry for the determination of volatile organic compounds ranging from C3 to C26 in soil gas samples using Method TO-17. Figures of merit such as breakthrough, precision, linearity, and detection capability are presented, in addition to an evaluation of its real-world capability at sites with moderate diesel and semivolatile polynuclear aromatic hydrocarbon (up to pyrene) contamination, in the presence of high humidity. This research has provided a means to determine a more representative composition of soil gas.

产品与服务 (154)
Filters:

Filters :

产品类型
  • Consumables (135)
  • Accessories (15)
  • Instruments (3)
  • Software and Informatics (1)
应用
  • Mass Spectrometry (40)
帽和载波风格
  • Screw Top (26)
  • Crimp Top (19)
  • Snap Top (12)
颜色
  • Clear (40)
  • Silver (13)
  • Blue (12)
  • Black (9)
  • Amber (8)
  • Gray (2)
  • Green (1)
  • White (1)
  • Red (1)
内径
  • 11 mm (39)
  • 9 mm (21)
  • 8 mm (11)
  • 10 mm (10)
  • 20 mm (3)
  • 13 mm (3)
长度
  • 51-100 (1)
材料
  • Clear Glass (42)
  • PTFE/Silicone (Pre-Slit) (15)
  • PTFE/Silicone (12)
  • PTFE/Red Rubber (12)
  • Amber Glass (11)
  • PTFE/Silicone/PTFE (4)
  • Clear Polyethelene (2)
  • PTFE/Buytl (2)
  • Clear Plastic with Slit (1)
  • Clear Plastic (1)
  • Polypropylene (1)
  • Aluminum/PTFE (1)
  • Polyethylene (1)
  • Amber Polyethelene (1)
  • Phenolic (1)
  • Black Viton (1)
  • PTFE (1)
  • Silicone (1)
温度-最高
  • 20-30 (3)
  • 30-40 (3)
温度-最低
  • 0-10 (3)
  • 10-20 (3)
产品品牌名称
  • Torion? (34)
  • Custodion? (5)
  • Clarus (3)
  • Clairion? (2)
产品组
  • Cap/Septa (33)
  • Kit (24)
  • Vial (19)
  • Vial Insert (15)
  • Clarus SQ 8T (1)
  • Decapper (1)
  • Vial Sleeve (1)
  • Mass Spectral Library (1)
  • Sample Support (1)
  • Vial Rack (1)
  • Clarus SQ 8S (1)
  • Benchtop Crimper (1)
  • Clarus SQ 8C (1)
类型
  • Screw Top (41)
  • Crimp Top (24)
  • Snap Top (18)
技术
  • Gas Chromatography/Mass Spectrometry (5)
技术类型
  • Autosampler (91)
  • Headspace (3)
  • Chromatography (2)
体积容量
  • 2 mL (68)
  • 300 μL (4)
  • 250 μL (3)
  • 200 μL (3)
  • 150 μL (1)
  • 4 mL (1)
  • 400 μL (1)

1-12 的 154 产品与服务

  • Jump to:
香港黄大仙码报要钱料